LCR METER 소자측정기

(해외배송 가능상품)
기본 정보
상품명 LCR METER 소자측정기
VAT포함 견적문의
모델 LCR-6002
상품요약정보 [주파수범위 10Hz~ 2kHz]
제조사 GWINSTEK
배송비 무료
수량 수량증가수량감소
옵션바로선택

개인결제창을 통한 결제 시 네이버 마일리지 적립 및 사용이 가능합니다.

상품 옵션

상품 옵션
옵션 선택

(최소주문수량 1개 이상 / 최대주문수량 0개 이하)

사이즈 가이드

상품 목록

구매하기

상품 목록
상품명 상품수 가격
LCR METER 소자측정기 수량증가 수량감소 견적문의 (  )
총 상품금액(수량) : 0 (0개)

할인가가 적용된 최종 결제예정금액은 주문 시 확인할 수 있습니다.

이벤트

Consecutive frequency and Convenient zero function

The LCR-6000 series, within the provided frequency range, features consecutive and adjustable frequency capability which allows users to conduct measurement and analysis on components with the most genuine frequency requirements. For OPEN/SHORT fixture compensation function, the LCR-6000 series is equipped with full frequency range zero and spot zero selections. After executing full frequency range zero, users, under the conditions of not turning off the power and not changing test fixture, can freely change test frequency for the LCR-6000 series to execute component measurements that tremendously saves time in repeatedly zeroing test fixture after changing frequency.

01
 Consecutive and adjustable frequency
 Freely input frequency within provided frequency range

02
Selectable fixture zeroing methods
 Full frequency range zero or spot zero

Rich and diverse information display

The measurement result display of the LCR-6000 series not only reveals primary and secondary measurement parameters but also includes two monitoring parameters. Therefore, four DUT related parameters can be simultaneously shown on the display screen to save time if repeated measurements are required. With respect to display screen, the LCR-6000 series features diverse display to meet users’ observation requirements. For instance, MEAS display shows setting parameters and measurement results at the same time; ENLARGE display focuses on measurement results and PASS/FAIL judgment is available, which is conducive to assist engineers to swiftly obtain the validity of measurement results.

01
 MEAS display
Parameter setting and four measurement parameters 

02
ENLARGE display
Enlarge measurement results and include PASS/FAIL judgment

10 points listed tests and PC software

The LCR-6000 series provides the 10 points listed test function, which allows users to define a set of DUT measurement parameters (such as Cs- Rs) and to set 10 test criteria of category (either by frequency or by voltage or by current) but different values to conduct measurements. Through this function, users can rapidly and clearly obtain DUT’s characteristic variation trend to determine the adaptability of DUT’s practical applications. The measurement results can be recorded directly in the internal memory and be transferred to the PC through USB. The LCR-6000 series also provides free PC software (maximum 1,000 points listed tests) in order to satisfy users’ analytical requirements on delicate variation.

01
 Listed tests
Variation criteria based upon frequency or voltage/current

02
On software ─ characteristic curve
Provide more delicate characteristic variation trend

Diverse ancillary measurement functions

To satisfy the diverse measurement application requirements for different components and materials, the LCR-6000 series collocates with many auxiliary measurement functions. For capacitor measurement, Automatic Level Control (ALC) is mainly for component which requires a constant or rated test voltage such as multi-layer ceramic capacitor (MLCC). An internal D.C. bias voltage (±2.5V, internal) is allowing simulating A.C. and D.C. coexistence to learn capacitance variation. For inductor measurement, the D.C. resistance measurement function is to validate D.C. resistance characteristics. Additional, the LCZ function is to quickly identify components ’characteristics. When the function is activated, the LCR-6000 series will automatically determine DUTs’ characteristics and reveal the optimum parameters to show the measurement results.

01
Automatic level control
Ideal for measuring components with voltage requirements

02
Internal bias (±2.5V adjustable)
Ideal for capacitive components’ characteristic tests  

01
 D.C. resistance measurement
Ideal for inductive components’ D.C. characteristics verification

 

Standard Interface

For interface connectivity, the LCR-6000 series comes equipped with handler interface and RS-232C interface. Handler outputs 10 BIN (9BIN, AUX: 1BIN) sorting results that is best for external connection control, for instance, connecting to a sorting machine to conduct components’ sorting operation. RS-232C is suitable for remote control and measurement results retrieval. The PC gives commands to control settings or to read measurement results so as to achieve the requirements of verifying automotive applications.

02

 

TEST FREQUENCY

 

LCR-6300: 10Hz~300kHz(±0.01%) (4 digits resolution)
LCR-6200: 10Hz~200kHz(±0.01%) (4 digits resolution)
LCR-6100: 10Hz~100kHz(±0.01%) (4 digits resolution)
LCR-6020: 10Hz~ 20kHz(±0.01%) (4 digits resolution)
LCR-6002: 10Hz~  2kHz(±0.01%) (4 digits resolution)

OUTPUT IMPEDANCE

 

30Ω / 50Ω / 100Ω selectable

BASIC ACCURACY

Slow / Med

0.05%

Fast

0.1%

TEST SPEED

 

FAST:25ms / MED:100ms / SLOW:333ms

TEST SIGNAL LEVELS

Voltage

10.00mV- 2.00V (±10%)   CV :10.00mV- 2.00V(±6%)

Current

100.0uA- 20.00mA (±10%) CC :100.0uA- 20.00mA(±6%) (@2VMax)

DC BIAS

Internal

±2.5V (0.5%+0.005V)

DISPLAYRANGE

R, X, |Z|

G, B, |Y|

L

C

D

Q

θd

θr

DCR

Δ%

0.00001Ω ~ 99.9999MΩ

0.01nS ~ 999.999S

0.00001uH ~ 9999.99H

0.00001pF ~ 9999.99mF

0.00001 ~ 9.99999

0.00001 ~ 99999.9

-179.999° ~ 179.999°

-3.14159 ~ 3.14159

0.00001Ω ~ 99.9999MΩ

-99999% ~ 99999%

TEST MODE

16 Combinations

Cs-Rs, Cs-D, Cp-Rp, Cp-D, Lp-Rp, Lp-Q, Ls-Rs, Ls-Q,
Rs-Q, Rp-Q, R-X, Z-θr, Z-θd, Z-D, Z-Q, DCR

Monitor parameter (2 selectable)

Z, D, Q, Vac, Iac, Δ, Δ%, θr, θd, R, X, G, B, Y

LISTED MODE

 

10 steps

BIN FUNCTION

 

Comparator (9BIN,AUX:1BIN)

MEMORY

INT – panel setting

10 file name

INT – measured data

10000 Data(.csv)

USB storage

10 file name for setting, 9999 file name for data, 999 Log file for LCD screen

OTHER FUNCTION

Auto Level Control (ALC)

ON/OFF

Average

1~256 times

Trigger

INT / MAN / EXT / BUS

Delay

0ms~60s

Judgment

PASS / FAIL

Auto LCZ

ON / OFF

Screen Capture

Saving in to USB (Bmp form)

DISPLAY

 

3.5'LCD, RGB color (320x240)

INTERFACE

 

RS-232(SCPI), Handler, USB Host

POWER SOURCE

 

AC 90V-250V, 50-60Hz, Max. 30VA

DIMENSION & WEIGHT

 

265(W)x107(H)x312(D) mm, Approx.3kg


 

상품결제정보

고액결제의 경우 안전을 위해 카드사에서 확인전화를 드릴 수도 있습니다. 확인과정에서 도난 카드의 사용이나 타인 명의의 주문등 정상적인 주문이 아니라고 판단될 경우 임의로 주문을 보류 또는 취소할 수 있습니다.  

무통장 입금은 상품 구매 대금은 PC뱅킹, 인터넷뱅킹, 텔레뱅킹 혹은 가까운 은행에서 직접 입금하시면 됩니다.  
주문시 입력한 입금자명과 실제입금자의 성명이 반드시 일치하여야 하며, 7일 이내로 입금을 하셔야 하며 입금되지 않은 주문은 자동취소 됩니다.

배송정보

배송 방법 : 택배
배송 지역 : 전국지역
배송 비용 : 무료
배송 기간 : 3일 ~ 7일
배송 안내 : - 산간벽지나 도서지방은 별도의 추가금액을 지불하셔야 하는 경우가 있습니다.
고객님께서 주문하신 상품은 입금 확인후 배송해 드립니다. 다만, 상품종류에 따라서 상품의 배송이 다소 지연될 수 있습니다.

교환 및 반품정보

교환 및 반품이 가능한 경우
- 상품을 공급 받으신 날로부터 7일이내 단, 가전제품의
  경우 포장을 개봉하였거나 포장이 훼손되어 상품가치가 상실된 경우에는 교환/반품이 불가능합니다.
- 공급받으신 상품 및 용역의 내용이 표시.광고 내용과
  다르거나 다르게 이행된 경우에는 공급받은 날로부터 3월이내, 그사실을 알게 된 날로부터 30일이내

교환 및 반품이 불가능한 경우
- 고객님의 책임 있는 사유로 상품등이 멸실 또는 훼손된 경우. 단, 상품의 내용을 확인하기 위하여
  포장 등을 훼손한 경우는 제외
- 포장을 개봉하였거나 포장이 훼손되어 상품가치가 상실된 경우
  (예 : 가전제품, 식품, 음반 등, 단 액정화면이 부착된 노트북, LCD모니터, 디지털 카메라 등의 불량화소에
  따른 반품/교환은 제조사 기준에 따릅니다.)
- 고객님의 사용 또는 일부 소비에 의하여 상품의 가치가 현저히 감소한 경우 단, 화장품등의 경우 시용제품을
  제공한 경우에 한 합니다.
- 시간의 경과에 의하여 재판매가 곤란할 정도로 상품등의 가치가 현저히 감소한 경우
- 복제가 가능한 상품등의 포장을 훼손한 경우
  (자세한 내용은 고객만족센터 1:1 E-MAIL상담을 이용해 주시기 바랍니다.)

※ 고객님의 마음이 바뀌어 교환, 반품을 하실 경우 상품반송 비용은 고객님께서 부담하셔야 합니다.
  (색상 교환, 사이즈 교환 등 포함)

서비스문의




앗! 화면폭이 너무 좁아요.
브라우져의 사이즈를 더 늘여주세요~

좁은 화면으로 보실 때는 모바일 기기에서
최적화된 화면으로 쇼핑을 즐기실 수 있어요~

     

    CUSTOMER CENTER

    BANK INFO

    • 예금주